How to operate ammonia compressor safely?
How to operate an ammonia compressor safely? An ammonia compressor compresses gaseous ammonia into liquid ammonia. The compressor is piston-type. So how to operate an ammonia compressor safely?
1. Operation process
1. Start the water pump to circulate the water.
2. Open the exhaust stop valve, the valves before and after the oil filter, and the gauge valve.
3. Turn on the power control switch and check whether the voltage, control light and oil level are normal.
4. Start the oil pump. After it runs normally, open the cooling water valve of the oil cooler.
5. Check whether the energy indication is at zero position and turn the 4-way valve handle to the load-reducing position.
6. Start the compressor, open the suction stop valve, and check whether the oil pressure is higher than the exhaust pressure by 0.150.3MPa.
7. Increase the load several times and open the liquid supply valve accordingly. If the unit operates normally, continue to increase the load to the required energy position, then move the 4-way valve handle to the stop position to allow the unit to continue operating under normal conditions.
8. After the unit is running normally, please pay attention to check and record the suction pressure, exhaust pressure, suction temperature, exhaust temperature, oil temperature, voltage and current value in time.
2. Normal shutdown
1. Turn the energy conditioning 4-way valve handle to the load reduction position, close the liquid supply valve, and close the air intake stop valve.
2. When the slide valve returns to the 4050 percent position, press the host stop button. After the host stops running, close the suction stop valve.
3. After the load is reduced to zero, press the oil pump stop button. The water pump will be stopped or turned on depending on the application.
4. Cut off the power supply of the unit.
Related News
- How to adjust the air volume of the air compressor?
- The status quo and development trend of compressor technology
- Knowledge about daily maintenance of air compressors
- Reasons for lack of compressor displacement
- What are the common faults of compressors?
- Maintenance of natural gas compressor
- Safe use of vinyl chloride compressors
- Analysis of several common failures of dimethyl ether compressor
- The structure and characteristics of vinyl chloride compressor
- How to maintain the vinyl chloride compressor?
- What are the maintenance methods for ammonia compressors?
- Analysis of the Mechanism of Oil Lack in Compressor
- Factors affecting air compressor energy consumption
- How to operate an ammonia compressor
- How to choose a compressor
- The principle of compressor
- Fire extinguishing system for air compressor
- Application range of air compressor
- The use of oxygen compressor
- Working principle of biogas compressor